A 5.25" dual drive bay slot reservoir/pump combo with high-quality POM and PMMA design


Pacific PR2U Pump/Reservoir Combo

Thermaltake presents the new Pacific PR2U reservoir and D5 pump for the ultimate in custom PC watercooling configurations. Featuring exceptional performance and unrivalled reliability, the PR2U fits into an empty dual 5.25" drive bay slot and is manufactured from high quality POM and PMMA material to provide a crystal clear, high performance, and durable solution.

Tt LCS Certified

Tt LCS Certified is a Thermaltake exclusive certification applied only to products that pass the design and hardcore enthusiasts standards that a true LCS chassis should hold to. The Tt LCS certification was created so that we at Thermaltake can indicate to all power users which chassis have been tested to be best compatible with extreme liquid cooling configurations, ensuring you get the best performance from the best features and fitment.

Sturdy & Durable Design

Manufactured in Taiwan, the Pacific PR2U pump and reservoir is made of reliable, light-weight POM and 6mm thickness PMMA front panel, making it crystal clear and highly durable.

Ultimate Speed Controller and High-lift Pumping

The PR2U pump and reservoir combo is designed with a manual speed control knob to provide five speeds. Maximum discharge up to 1135L/hr provides high-performance cooling to your components. High-lift pumping of the pump head reaches up to 15 feet high at the maximum speed. Enthusiasts can build up advanced liquid cooling loop, two GPUs, three radiators, or even more LCS components at the same time.
The pump is compatible with Thermaltake Pacific Series fittings, further increasing system performance, providing ultimate control for your water cooling system.


Maximum Compatibility

Five pre-drilled G1/4 holes and one pressure equalizer maximize compatibility. Easily refill coolant by removing the plugs in the front and rear.

Easy & Flexible Application

Pacific PR2U allows enthusiasts to build a superior water cooling system from an aesthetic standpoint and incorporate externally-modular upgrades into their chassis.


Cautions

Thermaltake recommends the following steps to be taken before using the Pacific series radiators and water blocks

  • To ensure a clean loop, flush and rinse your radiators and water blocks with distilled water prior to use.
  • Do not use tap water or distilled water as your coolant, it may harm your loop and reduce performance.
  • It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance while protecting the entire liquid loop from corrosion.
  • Before storing your water cooling components, please clean, rinse and dry. This will ensure a longer lifespan for your components.

Thermaltake recommends the following steps to be taken after completing your water loop setup

  • It is strongly recommended to use market proven pre-mix coolant, such as Thermaltake Coolant 1000. It offers great performance while preventing the entire cooling system – copper, brass, nickel, aluminum, and steel – from corrosion.
  • Fill the reservoir with coolant and cycle the power on and off several times while the pump pushing the coolant into the loop.
  • DO NOT let the pump run dry, when there is no liquid entering the pump turn off your power immediately
  • Fill the reservoir to the top as it will prevent air from going into the pump
  • If necessary tilt the system slightly from side to side to bleed the air out of the loop.
  • Place some paper towels under fittings and joining points to test for leaks.
  • Run the loop with the fill port open for about 24 hours to completely bleed the air out of the loop.

Cautions

Thermaltake recommends the following steps to be taken before using the Pacific series radiators and water blocks:

  • To ensure a clean loop, flush and rinse your radiators and water blocks with distilled water prior to use.
  • Do not use tap water or distilled water as your coolant, it may harm your loop and reduce performance.
  • It is strongly recommended to use market-proven pre-mix coolant, such as Thermaltake Coolant 1000, which offers great performance while protecting the entire liquid loop from corrosion.
  • Before storing your water cooling components, please clean, rinse, and dry. This will ensure a longer lifespan for your components.

Thermaltake recommends the following steps to be taken after completing your water loop setup:

  • It is strongly recommended to use market-proven pre-mix coolant, such as Thermaltake Coolant 1000, which offers great performance while preventing corrosion in the entire cooling system (copper, brass, nickel, aluminum, and steel).
  • Fill the reservoir with coolant and cycle the power on and off several times while the pump pushes the coolant into the loop.
  • DO NOT let the pump run dry. If no liquid is entering the pump, turn off your power immediately.
  • Fill the reservoir to the top to prevent air from entering the pump.
  • If necessary, tilt the system slightly from side to side to bleed the air out of the loop.
  • Place paper towels under fittings and joining points to test for leaks.
  • Run the loop with the fill port open for about 24 hours to completely bleed the air out of the loop.
  • Before starting, flush out your system properly to prevent any coolant or unwanted particles from sticking to your tubes, radiators, and other cooling components.
  • Coolant might fade over time.
More Information
P/N CL-W085-PL00BL-A
Dimensions 84.8 (H) x 147.9 (W) x 104.9 (L) mm
Weight 933 g
Connector 4 Pin
Pump Speed P1: 1,800 RPM
P2: 2,550 RPM
P3: 3,300 RPM
P4: 4,050 RPM
P5: 4,800 RPM
MATERIAL POM + PMMA
CAPACITY 250 ml
Maximum head 15 feet (4.5m)
Maximum pressure 50 PSI
Input Voltage 8 ~ 24 V
Parts 1. Stopper *3 (G 1/4 )
2. Pressure Equalizer Plug *1
Screw thread G 1/4